PDC designs rugged Metering Syringe Pumps for an extremely accurate injection of fluids
irrespective of viscosity into a system at a consistent flow and constant output pressure.
We design single and double barrel syringe pumps for batch and continuous flow operations.
In a continuous flow operation, one barrel is discharging fluid, while the other retracts,
pressurizes to set pressure and gets ready for transfer.
High Pressure Syringe Pumps Standard Features Include:
- Flow Rates: Programmable flow rate range from (0.004 mL/min to 400 mL/min) to (0.4 mL/min to 400 mL/min)
- Flow Characteristics: Pulseless, linear output flow
- Accuracy and repeatability of flow +/-0.05% of set point
- Discharge Pressures: Up to 60,000 psi (4,100 bar)
- Pump Barrel Temperature: Up to 450 °F (232 °C)
- Barrel Capacities: 125 cc to 1500 cc
- Simplex (single) Barrel Design: Batch operation
- Duplex (two) Barrel Design: Continuous operation
- Plunger & Barrel Materials of construction: Available in Stainless Steel, Hastelloys, Inconels, Monels, Nickel, Titanium for process compatibility
- Stationary Seals: Double, self-energizing, adjustable with leak port for collection of leaks for mass balance
- Packing: Standard is graphite filled teflon (PTFE), other packing materials are optional
- Drive Motors: Servo, Inverter Duty
PLC based and relay logic user-friendly controls make it easy for the operator to set system
parameters such as pressure and flow rates. Customer has option of local control/ display
panel mounted on skid or remotely linked to DCS interface inputs or PC based MMI.
For simplex designs, control/display panel is supplied loose for customer local or remote mounting.
PDC's syringe pumps can be located in Class 1, Divisions 1& 2, Groups B, C, D:
All Components on pump skid are wired to a local Nema 7,9 junction box.
Pump controller (enclosed in a Nema 4,12 junction box) is supplied loose for mounting in a non-classified area, or pump controller can be mounted locally if purged.
Inter-connecting wiring is done by customer after skid and pump controller are installed.
- High -speed reverse for fast barrel filling
- Electrically heated barrel (s)
- Jacketed barrels for heating/cooling by customer
Electrical Requirements
Per customer specifications.