Duplex syringe pump with 125 cc barrel capacity. Flow rate is 0.025 Ml/min to 25 Ml/min. Working pressure is 1000 psi at 110 oF. Pump is rated for class 1, Div.II. Control panel is remotely located.
Duplex syringe pump. 500 cc each barrel capacity. Flow rate range from 5 cc/hr to 100 cc/hr at 2000 psi working pressure and 72 oF temperature. Control panel is locally mounted.
Duplex syringe pump with 1500 cc each barrel capacity. Designed for 400 psi working pressure. Flow rate range is 6.00 ml/min. to 225 ml/min. Rated for class 1, div. II. Control panel remotely installed.
Simplex syringe pump, 75 cc barrel capacity. Flow rate 10 cc to 100 ml/min at 200 psi working pressure and 200 oF temp. Pump is rated for general purpose.
1875 Stout Drive, Warminster PA 18974 USA • Voice: 215-443-9442 • Fax: 215-443-8530 • E-mail: info@pdcmachines.com